PLATE
/ BATTERY CHARGER |
| INTRODUCTION :- |
The Ultimate power to fight
fluctuation of voltage & current. |
We are the pioneer in manufacturing
of Automatic Constant Current Chargers for plates and
battery charging. We manufacture Chargers of different
capacities covering a wide range of voltage from 0 to
300 volts DC and current range from 10 Amps.
to 200 Amps. It is generally observed while using convensional
charger it's charging current varies with the variation
of voltage, which causes damage to plates and also
to the charger itself. The second problem is faced of
falling down of current as the plates or batteries gets
charged. To control variation of current during formation,
we manufacture Constant Current Chargers having the following
technical specifications and main advantages. |
 |
SALIENT FEATURES
- Maintains constant
current at the load.
- No effect of voltage
variation on output current.
- Maintains the
quality of plates and saves time period.
- Controls over-loading
of our electrical supply system.
- Reduction in failure
rate of electrical equipments up to 80%.
- Energy saving
up to 10% to 15% possible.
- Uniform quality
of end products.
|
PLC Controlled
Plate Charger |
|
|
|
|
Manual Battery
Charger
72V/10A, 72V/15A, 96V/15A |
Plate Charger
|
|
| |
|
 |
Inner view
of plate charger |
| SPECIFICATIONS |
| Input Voltage |
: |
380/400 Volts AC, three
phase. 50 Hz. |
| Output Voltage |
: |
Zero to 300 volts D.C. Or above. |
| Output Current |
: |
Zero to 30-40-50-60-80 to 100 Amps.
|
| Output Current of Double Circuit |
: |
30-40-50 x two circuits. (Double output) |
| Wave Form |
: |
Full wave |
| Temperature Rise |
: |
Less than 35° C above Ambient
at the top of the oil. |
| Efficiency |
: |
Not less then 90%. |
| Insulation |
: |
`A` Class for oil cooled. |
| Cooling |
: |
Oil Cooled. |
| Current Control |
: |
Stepless Current with Electronic Controller.
|
|
|
CIRCUIT
|
| The circuit applied
in our charger is simple and universal. A.
C. Supply is given to a double wound transformer.
The output voltage of the Secondary is variable
steplessly and output is given to bridge circuit.
An electronic controller is provided to control
constant current. |
|
COMPONENTS
|
| DOUBLE
WOUND TRANSFORMER : |
Silicon stamping &
Electrolytic copper is used for construction
of double wound transformer.
Transformer is double wound with primary delta/star
connection and secondary star connection.
RECTIFIER : Superior
quality silicon diodes are provided for converting
AC to DC with sufficient current capacity
& high PIV. METER PANEL
: Three phase indicating lamps along
with output voltmeter & Ammeter are provided
on a panel. DC current controller is provided
to control constant current.
GUARANTEE
: Our chargers are guaranteed for
a period of 24 months from the date of sale
against any manufacturing defects.
* NOTE : PLC
9 stage current controller Plate charger is
Also Available. |
|
|
| |
|